Code: EC-6500ET

6 Zone Voice Evacuation Router EC-6500ET (500W) Features: The router is needed for more than 6 zone voice alarm system. Built-in 500W 6 zone class-D amplifier. With same function with EVAC-500 voice alarm controller except control function. The expansion router will be controlled by master voice alarm controller. Integration of EVAC controller, paging system, PA system & BGM system together. Built-in two separate players for EVAC and alert voice message by SD card. Built-in 6 zone AB speaker line low impedance supervision. Built-in amplifier auto changeover into standby when fault. With external amplifier input to expansion the power. Capacity of connection 32 remote microphones. 6 zone speaker outputs with separate zone volume control (ATT). 6 zone separate indicator for EVAC, fault, music/paging & select. System indicators of AC, DC, fault and indicators for EVAC & alert. Zone capacity of 120 zones by cascaded 19 routers. With 8 programmable control inputs and 8 programmable control outputs for voice evacuation system. With Fault, EVAC outputs and Reset input for third party system integration. Priority level: fireman microphone, EVAC, input 1, remote microphone, timer & BGM. Two combo inputs for microphone/line, 4 line inputs and one REC output. Two RJ45 ports for router, two RJ45 for remote microphone input and two RJ45 for LAN/WAN/Internet network. IP network module for optional to buy. AC 230V and DC24V battery input. Auto switch into the battery backup when AC fails Rear Panel: 6 Zone Voice Evacuation Controler ECX-6500 (500W) Specifications: Model EC-6500ET Description 6 Zone Voice Evacuation Amplifier Rated Power Output 500W Fireman Microphone 5Mv, 600Ω Line 1-2 Inputs 385mV, 10kΩbalanced Combo Line 3-6 Inputs 350mV, 10kΩ, RCA Frequency Response 80Hz~20kHz THD <1% at RMS,1KHz S/N Ratio >70dB Speaker Output 100V AB 8 zone speaker outputs REC Output 200mV Control Input & Output 8 programmable control inputs: Max 3.3V (voltage mode) or 0V closed contact 8 programmable control outputs: 0V closed contact; Control output for fault & EVAC: 0V closed contact; Reset control input: 0V closed contact Voice Message MP3 or WMA format, two separate players of SD card with protection cover, programmable voice message up to 255, 10 years valid Event Record HEX format, Hard Flash memory, events up to 1000 records, 10 years valid Operation Environment Operation Temp: +5℃ ~ +40℃; Store Temp: -20℃ ~ +70℃; Operation Humidity: Power Consumption 600W Power Supply AC230V or 115V & DC24V battery inputs, 50-60HZ AC Fuse 250V/6.3A, slow type and restorable fuse Dimension 484(W)×132(H)×449(D) mm Weight 24kg System Connection Diagram:

Technical specifications

Model
EC-6500ET
Description
6 Zone Voice Evacuation Amplifier
Rated Power Output
500W
Fireman Microphone
5Mv, 600Ω
Line 1-2 Inputs
385mV, 10kΩbalanced Combo
Line 3-6 Inputs
350mV, 10kΩ, RCA
Frequency Response
80Hz~20kHz
THD
<1% at RMS,1KHz
S/N Ratio
>70dB
Speaker Output
100V AB 8 zone speaker outputs
REC Output
200mV
Control Input & Output
8 programmable control inputs: Max 3.3V (voltage mode) or 0V closed contact 8 programmable control outputs: 0V closed contact; Control output for fault & EVAC: 0V closed contact; Reset control input: 0V closed contact
Voice Message
MP3 or WMA format, two separate players of SD card with protection cover, programmable voice message up to 255, 10 years valid
Event Record
HEX format, Hard Flash memory, events up to 1000 records, 10 years valid
Operation Environment
Operation Temp: +5℃ ~ +40℃; Store Temp: -20℃ ~ +70℃; Operation Humidity: <95%
Power Consumption
600W
Power Supply
AC230V or 115V & DC24V battery inputs, 50-60HZ
AC Fuse
250V/6.3A, slow type and restorable fuse
Dimension
484(W)×132(H)×449(D) mm
Weight
24kg

Applications

The router is needed for more than 6 zone voice alarm system.
Built-in 500W 6 zone class-D amplifier.
With same function with EVAC-500 voice alarm controller except control function.
The expansion router will be controlled by master voice alarm controller.
Integration of EVAC controller, paging system, PA system & BGM system together.
Built-in two separate players for EVAC and alert voice message by SD card.
Built-in 6 zone AB speaker line low impedance supervision.
Built-in amplifier auto changeover into standby when fault.
With external amplifier input to expansion the power.
Capacity of connection 32 remote microphones.
6 zone speaker outputs with separate zone volume control (ATT).
6 zone separate indicator for EVAC, fault, music/paging & select.
System indicators of AC, DC, fault and indicators for EVAC & alert.
Zone capacity of 120 zones by cascaded 19 routers.
With 8 programmable control inputs and 8 programmable control outputs for voice evacuation system.
With Fault, EVAC outputs and Reset input for third party system integration.
Priority level: fireman microphone, EVAC, input 1, remote microphone, timer & BGM.
Two combo inputs for microphone/line, 4 line inputs and one REC output.
Two RJ45 ports for router, two RJ45 for remote microphone input and two RJ45 for LAN/WAN/Internet network.
IP network module for optional to buy.
AC 230V and DC24V battery input. Auto switch into the battery backup when AC fails